Download Spec Sheet498.72 KB
Download 3D PDF497.17 KB
Download STP113.48 KB
Description
A cartridge valve designed to provide a variable flow restriction with positive shut-off.
Operation
The DNV-080 varies flow restriction by adjusting needle in or out and will shut off when fully closed. This valve will meter flow in either direction.
Features and Benefits
- Zero leakage at shut-off.
- Aluminum knob.
- Full range of adjustments.
- Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Flow gpm
11.0
Flow lpm
41.6
Cavity
- Operating Pressure: 3000 PSI (207 Bar)
- Flow:
- See PRESSURE DROP VS. FLOW graph.
- Nominal flow 11 GPM (41.6 L/min).
- Cv Flow Factor: (Full Open) .47
- Internal Leakage: 0 drops/min. at 3000 psi (207 bar)
- Temperature: -30°F to +250°F (-35°C to +120°C)
- Recommended Filtration:
- Critical Application-ISO 17/15/13
- Non-Critical Application-ISO 20/18/14
- Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
- In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).