Download Spec Sheet544.14 KB
Download 3D PDF774.44 KB
Download STP503.27 KB
Description
A cartridge valve designed to provide a variable flow restriction with positive shut-off.
Operation
The DNV-100 varies flow restriction by adjusting needle in or out and will shut off when fully closed. This valve will meter flow in either direction.
Features and Benefits
- Hardened seat for long life.
- Low leakage at shut-off.
- Aluminum knob and disc nut.
- Full range of adjustments.
- Adjustment may be locked in place.
- Positive shut-off.
- Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Flow gpm
12.0
Flow lpm
45.4
Cavity
- Operating Pressure: 3000 PSI (207 Bar)
- Flow: 12 gpm (45.4 L/min.) max. recommended input.
- Internal Leakage: 2 drops/min. max. at 3000 PSI (207 Bar) at shut-off.
- Temperature: -30°F to +250°F (-35°C to +120°C)
- Recommended Filtration: ISO 20/18/14
- Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
- In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).