DPV-080-34C-N-L

Download STP106.79 KB
Product Image
Schematic
Pressure Drop vs Flow
Dimensions
How to Order
Description

New for 2026!!!

A cartridge valve designed as a three-position, four-way proportional  solenoid valve.

Operation

When de-energized, the valve prevents flow at all ports. When the upper coil (S1) is energized, flow is allowed from port-3 to port-4, and from port-2 to port-1. When the lower coil (S2) is energized flow is allowed from port-3 to port-2, and from port-4 to port-1. 

Initial meter-in flow begins at a nominal 0.3 amp on a 12 VDC system, full flow of 2 gpm at a nominal 1.3 amp. The valve functions with industry -common controllers which provide PWM current input to 1.2 amps at 12 VDC.

Operation of Manual Override Option:  To override, pull the knurled knob to activate the “S1” coil function, or push the knurled knob to activate the “S2” coil function. Release the knurled knob to return to the center position. 

Features and Benefits

PWM Duty Cycle, Ramp Time, Current Limit, Dither Frequency and Amplitude, can be provided by consulting the factory.
Continuous-duty solenoid
Hardened precision spool and sleeve for long life
Efficient wet-armature construction
Manual override option
Industry common cavity

Specifications
Max Operating Pressure (psi)
3500
Max Operating Pressure (bar)
241
Flow gpm
2.0
Flow lpm
7.6
Cavity
Valve Style
Spool
  • Internal Leakage:  (Per land) 10 in3/min (164 ml/min) max at 3000 psi (207 bar)
  • Hysteresis:  Less than 7%
  • Temperature:  -30°F to +250°F (-35°C to +120°C)
  • Coil Rating:  Continuous from 85% to 110% of rated voltage
  • Minimum Pull-In Voltage:  85% of rated voltage at 3000 psi (207 bar)
  • Recommended Filtration:  Critical Application ISO 17/15/13
  • Fluids:  Mineral-based fluids.
  • Cavity:  080-4, see page 11.08.4