New for 2026!!!
A cartridge valve designed as a three-position, four-way proportional solenoid valve.
When de-energized, the valve prevents flow at all ports. When the upper coil (S1) is energized, flow is allowed from port-3 to port-4, and from port-2 to port-1. When the lower coil (S2) is energized flow is allowed from port-3 to port-2, and from port-4 to port-1.
PWM Duty Cycle, Ramp Time, Current Limit, Dither Frequency and Amplitude, can be provided by consulting the factory.
Continuous-duty solenoid
Hardened precision spool and sleeve for long life
Efficient wet-armature construction
Manual override option
Industry common cavity
- Internal Leakage: 246 cc/min max at 3000 psi (207 bar)
- Hysteresis: Less than 7%
- Temperature: -30°F to +250°F (-35°C to +120°C)
- Coil Rating: Continuous from 85% to 110% of rated voltage
- Minimum Pull-In Voltage: 85% of rated voltage at 3000 psi (207 bar)
- Recommended Filtration: Critical Application ISO 17/15/13
- Fluids: Mineral-based fluids.
- Cavity: 100-4