Download Spec Sheet842.12 KB
Download 3D PDF523.41 KB
Download STP129.94 KB
Description
A cartridge valve designed with positive shut off to be used in load holding applications.
Operation
When de-energized, the DSV2-100-2NCP acts as a check valve, allowing flow from ➀ to ➁, while blocking flow from ➁ to ➀.
When energized, the poppet lifts to open the ➁ to ➀ flow path.
Operation of Manual Override Option: To override, push button in, twist counterclockwise and release. In this position, valve will remain open in a detented condition.
To return to normal operation, push button in, twist clockwise and release. Override will be detented in this position.
Features and Benefits
- Continuous-duty solenoid.
- Hardened poppet and plunger for long life and low leakage.
- Efficient wet-armature construction.
- Cartridges are voltage interchangeable.
- Optional coil voltages and terminations.
- Filter screen standard.
- Manual override option.
- Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Flow gpm
16.0
Flow lpm
60.6
Cavity
Valve Style
Poppet
- Operating Pressure: 3000 PSI (207 Bar)
- Flow: See PRESSURE DROP VS. FLOW graph.
- Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
- Temperature: -30° F to +250° F (-35°C to +120° C)
- Coil Duty Rating: Continuous from 85% to 110% of rated voltage.
- Current Draw: 12 VDC is 1.8 amps.
- Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
- Response Time: 80% of final change of state with 100% voltage supplied at 100% of nominal flow rating.
- Pull-In: 12 VDC 100 m. sec.
- Drop-Out: 12 VDC 180 m. sec.
- Recommended Filtration:
- Critical Application-ISO 17/15/13
- Non-Critical Application-ISO 20/18/14
- Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
- In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).