ZCO-62

Download STP12.45 KB
Product Image
Schematic
Pressure Drop vs Flow
Dimensions
How to Order
Description

A cartridge valve designed to allow free flow in one direction, while preventing flow in the opposite direction. This valve is commonly used as a load-holding or blocking valve.

Operation

Pressure at ➀ overcomes the spring-bias poppet and allows free flow to ➁. Flow in the opposite direction, from ➁ to ➀, is blocked by the poppet.

Features and Benefits
  • Slip in style.
  • Zero leak.
  • Compact size.
Specifications
Max Operating Pressure (psi)
1500
Max Operating Pressure (bar)
103
Flow gpm
2.0
Flow lpm
7.6
Cavity
Valve Style
Poppet
  • Operating Pressure: 1500 PSI (103 Bar)
  • Flow:
    • See PRESSURE DROP VS. FLOW graph.
    • Nominal Flow 2 GPM (7.6 L/min).
  • Internal Leakage: 0 drops/min. max. at 1500 PSI (103 Bar)
  • Crack Pressure: 1 - 2 PSI (0.67-0.14 Bar)
  • Temperature: -30°F to +250°F (-35°C to +120°C)
  • Recommended Filtration:
    • Critical Application – ISO 17/15/13
    • Non-Critical Application – ISO 20/18/14
  • Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
  • Installation/Removal Tool: Consult factory
  • In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).