Download Spec Sheet452.35 KB
Download 3D PDF465.08 KB
Download STP50.38 KB
Description
A toggle-operated cartridge valve designed with positive shut off to be used in load holding applications.
Operation
The DTV2-080 blocks flow from ➁ to ➀, or ➀ to ➁. When the toggle handle is actuated, fluid flows from ➁ to ➀, or ➀ to ➁. The cartridge allows reverse flow from ➀ to ➁ after overcoming the spring force of 450 PSI (31 Bar).
The DTV2-080 can be actuated by pushing or pulling the toggle handle.
Features and Benefits
- Chrome alloy ball for long life.
- Push or pull actuator.
- Cannot over-center detent open (Safety purposes).
- Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Flow gpm
6.0
Flow lpm
22.7
Cavity
- Operating Pressure: 3000 PSI (207 Bar)
- Flow: See PRESSURE DROP VS. FLOW graph.
- Internal Leakage: 5 drops/min. max. at 3000 PSI (207 Bar)
- Temperature: -30° F to +250° F (-35°C to +120° C)
- Recommended Filtration:
- Critical Application-ISO 17/15/13
- Non-Critical Application-ISO 20/18/14
- Fluids: Mineral-based fluids. For other fluid compatibility consult factory.
- In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).