DFC-080

Download STP358.8 KB
Product Image
Schematic
Pressure Drop vs Flow
Dimensions
How to Order
Description

A cartridge valve designed to provide variable flow restriction in one direction with free flow in the opposite direction.

Operation

The DFC-080 varies flow restriction by adjusting needle in or out. Flow is metered from ➁ to ➀. Free reverse flow is from ➀ to ➁.

Features and Benefits
  • Hardened poppet and seat for long life.
  • Aluminum knob and disc nut.
  • Full range of adjustments.
  • Adjustment may be locked in place.
  • Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Max Operating Pressure (bar)
207
Flow gpm
10.0
Flow lpm
37.9
Cavity
  • Operating Pressure: 3000 PSI (207 Bar)
  • Flow: 10 gpm (37.9 L/min.) max recommended input.
  • Temperature: -30°F to +250°F (-35°C to +120°C)
  • Recommended Filtration: ISO 20/18/14
  • Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
  • In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).