Female-to-Female
      
            Download Spec Sheet220.38 KB
      
            Download 3D PDF317.61 KB
      
            Download STP350.38 KB
      
  
  
  
  
  Description
              The Pneu-Trol air bleed valve is used to remove trapped air from a hydraulic system, allowing system pump to prime itself. The valve will pass air or a small amount of oil with pump pressure below 50 psi (3.4 bar). Trapped air in the system is bled off back to the reservoir until a solid stream of hydraulic fluid at +50 psi (3.4 bar) closes the valve. This is automatic during every system start-up. The valve should be installed at the high point of the hydraulic system using a tee connection.
Features and Benefits
              - For hydraulic applications only
- Removes air trapped in hydraulic system
Specifications
      
  Max Operating Pressure (psi)
              5000
          Port Size
              1/4"
          Port Type
              NPTF
          Material
              Steel
          - Maximum Operating Pressure (non-Shock Service)
	- Carbon Steel: 5,000 psi (345 bar)
 
- Minimum Seating Pressure
	- 50 psi (3.4 bar)
 
- Operating Temperature range (O-ring)
	- Buna N: -307° to +400° F (-34° to +204° C)
 
- Threads
	- NPTF 1/4"
 
- Orifice Diameter
	- .089 (2.3)
 
- Materials
	- Body: Steel
- Spring: Stainless Steel 302
- Ball: Stainless Steel 440
- Washer: Steel
- Retainer Ring: Steel
 


 
 
 
 