New for 2026!

A cartridge valve designed as an electro-proportional, pressure compensated, normally closed, flow control valve.

The DPFR2-100-2NC model is an internally-compensated, proportional  flow control cartridge valve.  This valve has consistent flow regardless of the load  pressure, resulting in consistent machine behavior.  The DPFR2-100-2NC improves productivity with precise control of machine motion and speed.

Features and Benefits

•    PWM Duty Cycle, Ramp Time, Current Limit, Dither Frequency and Amplitude, can be provided by consulting the factory.
•    Continuous-duty solenoid
•    Hardened precision spool and sleeve for long life
•    Efficient wet-armature construction
•    Industry common cavity

Specifications
Max Operating Pressure (psi)
3000
Max Operating Pressure (bar)
207
Flow gpm
8.0
Flow lpm
30.3
Cavity
Valve Style
Spool
  • Internal Leakage:  420 cc/min max at 3000 psi (207 bar)
  • Hysteresis:  Less than 8%
  • Temperature:  -30°F to +250°F (-35°C to +120°C)
  • Coil Rating:  Continuous from 85% to 110% of rated voltage
  • Minimum Pull-In Voltage:  85% of rated voltage at 3000 psi (207 bar)
  • Recommended Filtration:  Critical Application ISO 17/15/13
  • Fluids:  Mineral-based fluids.
  • Cavity:  100-2