Download Product Brochure398.06 KB
Download 3D PDF537.55 KB
Download STP66.65 KB
Description
New for 2026!
A proportional cartridge valve designed with positive shut off to be used in load holding applications.
Operation
When de-energized, the DPV-080-2NCP acts as a check valve, allowing flow from ➀ to ➁, while blocking flow from ➁ to ➀. When energized, the poppet lifts to open the ➁ to ➀ flow path.
Features and Benefits
PWM Duty Cycle, Ramp Time, Current Limit, Dither Frequency and Amplitude, can be provided by consulting the factory.
Continuous-duty solenoid
Efficient wet-armature construction
Manual override option
Industry common cavity
Specifications
Max Operating Pressure (psi)
3000
Flow gpm
5.0
Flow lpm
18.9
Cavity
Valve Style
Poppet
- Internal Leakage: 5 drops/min max at 3000 psi (207 bar)
- Hysteresis: Less than 5% up to 85% I-Max, Less than 10% above 85% I-Max
- Temperature: -30°F to +250°F (-35°C to +120°C)
- Coil Rating: Continuous from 85% to 110% of rated voltage
- Minimum Pull-In Voltage: 85% of rated voltage at 3000 psi (207 bar)
- Recommended Filtration: Critical Application ISO 17/15/13
- Fluids: Mineral-based fluids.
- Cavity: 080-2