A cartridge valve designed as a normally closed, spool-type, proportional valve for use with a compensating element to provide an electrically variable pressure-compensated flow control.
As electrical current is applied to the coil, the spool will gradually shift from closed to open as current increases to 2 amps maximum. Flow will pass from port ➂ to port ➁ up to 300 psi differential.
Port ➀ is plugged.
The valve can also function as a differential control for load sense applications.
The valve functions with industry-common controllers which provide PWM current input to 2 amps @ 12 VDC.
OPERATION OF MANUAL OVERRIDE:
To override, push button in to activate. To return to normal function, release button.
- Valve controllers along with portable controller programming devices to vary PWM Duty Cycle, Ramp Time, Current Limit, Dither Frequency and Amplitude, can be provided by consulting the factory.
 - Hardened precision spool and sleeve for long life.
 - Efficient wet-armature construction.
 - Cartridges are voltage interchangeable.
 - Optional coil voltages and terminations.
 - Industry common cavity
 
- Coil: 12 volt system; Resistance 4.0 ohms @ 20˚C; Threshold Current 300 ± 70mA;
- Max. Control Current 1500 ± 200mA
 - 24 volt system; Resistance 16.0 ohms @ 20˚C; Threshold Current 150 ± 35mA;
 - Max. Control Current 750 ± 100mA
 
 - Operating Pressure: 3000 psi (207 bar)
 - Flow: See PRESSURE DROP VS. FLOW CURVE.
 - Internal Leakage: (Per land) 10 cu in3/min (164 cc/min) max. at 3000 psi (207 bar)
 - Temperature: -30°F to +250°F (-35°C to +120°C)
 - Coil Duty Rating: Continuous from 85% to 110% of rated voltage.
 - Recommended Filtration: ISO 16/12
 - Fluids: Mineral-based fluids.
 - In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 psi (207 bar)
 