Download Spec Sheet527.32 KB
ddsv-080-2ncp_3d.zip534.19 KB
Description
A cartridge valve designed with positive shut off, low leakage, to be used in load holding applications where system requires redundant methods of operation.
Operation
When de-energized, the DDSV-080-2NCP acts as a check valve, allowing flow from ➀ to ➁, while blocking flow from ➁ to ➀.
When either the top primary or bottom redundant coil is energized, the poppet lifts to open the ➁ to ➀ flow path.
Features and Benefits
- Continuous-duty solenoid.
- Efficient wet-armature construction.
- Hardened poppet and seat for long life.
- Cartridges are voltage interchangeable.
- Optional coil voltages and terminations.
- Filter screen standard.
- Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Flow gpm
5.0
Flow lpm
18.9
Cavity
Valve Style
Poppet
- Operating Pressure: 3000 PSI (207 Bar)
- Flow: See PRESSURE DROP VS. FLOW graph.
- Internal Leakage:
- 5 drops/min. max. at 3000 PSI (207 Bar)
- Temperature: -30°F to +250°F (-35°C to +120°C)
- Coil Duty Rating: Continuous from 85% to 110% of rated voltage.
- Current Draw: 12 VDC is 1.3 amps.
- Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
- Response Time: 80% of final change of state with 100% voltage supplied at 100% of nominal flow rating.
- Pull-In: 12 VDC 16 m. sec.
- Drop-Out: 12 VDC 18 m. sec.
- Recommended Filtration:
- Critical Application – ISO 17/15/13
- Non-Critical Application – ISO 20/18/14
- Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
- In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).