DDSV-080-2NCP

Product Image
Schematic
Pressure Drop vs Flow
Dimensions
How to Order
Description

A cartridge valve designed with positive shut off, low leakage, to be used in load holding applications where system requires redundant methods of operation.

Operation

When de-energized, the DDSV-080-2NCP acts as a check valve, allowing flow from ➀ to ➁, while blocking flow from ➁ to ➀.

When either the top primary or bottom redundant coil is energized, the poppet lifts to open the ➁ to ➀ flow path.

Features and Benefits
  • Continuous-duty solenoid.
  • Efficient wet-armature construction.
  • Hardened poppet and seat for long life.
  • Cartridges are voltage interchangeable.
  • Optional coil voltages and terminations.
  • Filter screen standard.
  • Industry common cavity.
Specifications
Max Operating Pressure (psi)
3000
Max Operating Pressure (bar)
207
Flow gpm
5.0
Flow lpm
18.9
Cavity
Valve Style
Poppet
  • Operating Pressure: 3000 PSI (207 Bar)
  • Flow: See PRESSURE DROP VS. FLOW graph.
  • Internal Leakage:
    • 5 drops/min. max. at 3000 PSI (207 Bar)
  • Temperature: -30°F to +250°F (-35°C to +120°C)
  • Coil Duty Rating: Continuous from 85% to 110% of rated voltage.
  • Current Draw: 12 VDC is 1.3 amps.
  • Minimum Pull-In Voltage: 85% of rated voltage at 3000 PSI (207 Bar)
  • Response Time: 80% of final change of state with 100% voltage supplied at 100% of nominal flow rating.
  • Pull-In: 12 VDC 16 m. sec.
  • Drop-Out: 12 VDC 18 m. sec.
  • Recommended Filtration:
    • Critical Application – ISO 17/15/13
    • Non-Critical Application – ISO 20/18/14
  • Fluids: Mineral-based fluids. For other fluid compatibility, consult factory.
  • In-Line Body Material: Anodized 6061T6 aluminum alloy rated at 3000 PSI (207 Bar).